E. HYDRAULIC POWER UNIT FLUID FLUSH AND RENEWAL
1. Fully deploy the lift.
2. Slowly open the manual release valve to release the hydraulic pressure and lower platform to
ground level.
3. Loosen clamp fastening the tank to the pump.
4. Carefully pull tank from the bottom of the pump, and empty the tank into a proper waste fluid
container.
5. Reinstall tank onto the pump and tighten the tank clamp.
6. Remove the plug on the top of the tank. Fill the tank with new hydraulic fluid. Fill only with Texaco
No. 15 aircraft hydraulic fluid (or equivalent U.S. mil spec H5606E/F oil).
7. Close manual release valve.
8. Using manual back-up pump, manually raise platform to vehicle floor level and lower platform to
ground level. Repeat this cycle three times.
9. Slowly open the manual release valve to release the hydraulic pressure and lower platform to
ground level.
10. Repeat steps 4 through 6 and proceed to step 11.
11. Close manual release valve.
12. Refer to BLEEDING THE HYDRAULIC SYSTEM.