4-6
C. POWER CUT-OFF INTERLOCK INDICATOR DIAGNOSTICS
The purpose of an interlock system is to interfere with the operation of the lift if an unsafe condition is
present. When interlock systems are added to the lift, the light is an indication whether or not the interlock
is operating properly. The light is placed within the electrical system so that no matter which interlock
system/method is used, the light will be ON when the interlock allows operation of the lift and OFF when
the interlock has disabled the lift. When there is no interlock system installed, the light stays illuminated.
On all lift assemblies without the optional door operator, there is a light-assembly installed in the position
where the door operator circuit breaker would normally be mounted. The light indicates when power is
being supplied to the signal portion of the electrical system. The light will aid in diagnosing electrical
problems. Refer to Table [4-4]:
TABLE [4-4]: INTERLOCK INDICATOR TROUBLESHOOTING GUIDE
SYMPTOM POSSIBLE CAUSE
Light is not lit, lift does not
operate.
Control system circuit breaker is tripped.
Light is not lit, lift operates. Light needs to be replaced.
Light is lit, lift does not operate. If there is a problem with the lift electrical system, check the
power and/or the signal circuitry. Both may have to be
checked, but check the power circuitry first.
END OF TABLE
D. ELECTRICAL WIRING DIAGRAMS
For the definitions of the electrical diagrams, refer to the following paragraphs:
1. Color Codes
For the definitions of the standard wire color codes, refer to Table [4-5]:
TABLE [4-5]: COLOR CODE DEFINITIONS
LETTER COLOR LETTER COLOR
BK Black R Red
BL Blue VI Violet
BR Brown VI/BK Violet w/ Black
GN Green W White
GN/BK Green w/ Black W/O White w/ Orange
O Orange Y Yellow
O/BK Orange w/ Black Y/BK Yellow w/ Black
END OF TABLE