2-5
2. WIRING FOR OPTIONAL PUMP ENCLOSURE
For electrical installation of the optional pump enclosure, refer to Figure [2-4] and follow this
procedure:
FIGURE [2-4]: WIRING FOR OPTIONAL PUMP ENCLOSURE
a. Crimp the supplied ring terminals to the harness assembly as shown.
b. Route and connect the "Pump to Pendant Harness Extension" to the pump enclosure
assembly.
c. Attach the ring terminals to the terminal board as shown.
3. MAIN WIRING
Whether the vehicle electrical system is +12VDC or +24VDC, insulated return or chassis
ground, the electrical installation is similar. To install electrical power to the lift, follow this
procedure:
CAUTION
CHECK VEHICLE BEFORE DRILLING. DO NOT DRILL INTO FACTORY WIRING,
HYDRAULIC LINES, FUEL LINES, FUEL TANK, ETC.
a. At vehicle engine or battery compartment, mount supplied Main Circuit Breaker within 10 -
12" (25 - 30 cm) of battery.
b. Adjacent to lift hydraulic pump unit, drill one 3/4" (19.5-mm) hole through vehicle floor,
deburr hole, and install grommet.
c. Insert lift power cable harness through drilled hole.
CAUTION
WHEN ROUTING POWER CABLE, AVOID HAZARDS SUCH AS VEHICLE DRIVE
SHAFTS, MOVING SUSPENSION PARTS, EXHAUST SYSTEMS, ETC.
d. From beneath vehicle, run harness along vehicle frame to circuit breaker. Make sure
harness does not interfere with moving or hot parts and secure with cable ties every 18" (45
cm).
e. At engine compartment, cut and retain 12" (30 cm) section from end of harness RED wire.